FM-750 Display User Guide 83
Implement Application Controller 5
Use this option to view and adjust the following settings:
Swath Control
Use this option to view and adjust the following settings:
Rate control
Use this option to view and adjust the following settings:
Note – When sending a target rate to the Amazone controller that is higher than 99.9, the
display rounds to the nearest whole number. For example, 0-99.9 is not rounded. 101.4 is
rounded to 101.
Target Rate
Set the target application rate that will be sent to the Amazone controller. Enter a rate
between 0.0 - 11000.0.
Settings ... Notes ...
Implement width Enter a width between 1' 00" - 328' 01" (0.30 - 99.99 m).
Fence Nozzles Enter the locations of any fence nozzles.
Number of sections Enter a number between 1 - 10.
Settings ... Notes ...
Boom control Enter a width between 1' 00" - 328' 01" (0.30 - 99.99 m).
Coverage switching overlap Control the amount of boom switching overlap allowed before the
section will be switched by the system.
Enter a value between 1 - 99%.
Boundary switching overlap Control the amount of overlap on a boundary before the boom section
is switched off.
Enter a value between 1 - 99%.
On/Off valve latency Tune the section switching to allow for hardware delays.
Enter a time between 0.0 - 10.0 seconds.
Intentional overlap Set a distance to be overlapped when moving to an unsprayed area or
out of a sprayed area.
Enter a distance between 0' 00" - 32' 10" (0.00 - 10.00 m).
Settings ... Notes ...
On Application rates are sent from a prescription loaded in the display or the target rate
manually configured on the display.
Off The target rate must be set on the Amazone controller. The FM-750 display does not
send target rates to the controller. This is the default setting.