EasyManua.ls Logo

Trio Motion Coordinator MC216 - Halt; Initialise; Last_Axis

Trio Motion Coordinator MC216
566 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motion Coordinator Technical Reference Manual
Trio BASIC Commands 8-103
System Parameters and Commands
HALT
Type:
System Command
Description:
Halts execution of all running programs. The
STOP
command will stop a specific pro-
gram.
Example:
HALT ‘ Stop ALL programs
or
STOP “main”
Stop only the program calledMAIN
Note:
HALT
does not stop any motion. Currently executing, or buffered moves will con-
tinue unless they are terminated with a
CANCEL
or
RAPIDSTOP
command.
INITIALISE
Type:
System Command.
Description:
Sets all axis, system and process parameters to their default values. The parame-
ters are also reset each time the controller is powered up, or when an
EX
(software
reset) command is performed. When using Motion Perfect a “Reset the controller..
under the “Controller” menu performs the equivalent of an
EX
command
LAST_AXIS
Type:
System Parameter (Read Only)
Description:
In order to maximise the processor time available to BASIC, the Motion Coordinator
keeps a record of the highest axis number that is in use. This axis number is held in
the system parameter
LAST_AXIS.
Axes higher than
LAST_AXIS
are not processed.
LAST_AXIS
is set automatically by the system software when an axis command is
used.

Table of Contents