8-114Trio BASIC Commands
System Parameters and Commands
Trio Motion Technology
Example 2:
SCOPE(OFF)
Note:
The
SCOPE
facility is a “one-shot” and needs to be re-started by the
TRIGGER
com-
mand each time an update of the samples is required.
Note2:
Data saved to the TABLE memory by the
SCOPE
command is not placed in battery
backed memory so will be lost when power is removed.
SCOPE_POS
Type:
System Parameter (Read Only)
Description:
Returns the current index position at which the
SCOPE
function is currently storing
its parameters.
SELECT
Type:
System Command
Description:
Selects the current active program for editing, running, listing etc.
SELECT
makes a
new program if the name entered is not a current program.
When a program is
SELECT
ed the commands
EDIT, RUN, LIST, NEW
etc. assume
that the
SELECT
ed program is the one to operate with unless a program is specified
as in for example:
RUN progname
When a program is selected any previously selected program is compiled.
Note:
The
SELECT
ed program cannot be changed when programs are running.
Note 2:
Motion Perfect automatically
SELECT
s programs when you click on their entry in the
list in the control panel.