EasyManua.ls Logo

Trio Motion Coordinator MC216 - Page 513

Trio Motion Coordinator MC216
566 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motion Coordinator Technical Reference Manual
Using the Trio ActiveX Control 12-27
Input / Output Commands
Send
Description:
Performs the corresponding
SEND(…)
command on the Motion Coordinator
Syntax:
Send(Destination, Type, Data1, Data2)
Parameters:
Return Value:
TrioPC STATUS
.
Setcom
Description:
Performs the corresponding
SETCOM(…)
command on the Motion Coordinator
Syntax
Setcom(Baudrate, DataBits, StopBits, Parity, [Port], [Control])
Parameters:
Return Value:
TrioPC STATUS
.
short Destination:
Address to which the data will be sent
short Type:
Type of message to be sent:
1. Direct variable transfer
2. Keypad offset
short Data1:
Data to be sent. If this is a keypad offset message then
it is the offset, otherwise it is the number of the vari-
able on the remote node to be set.
short Data2:
Optional numeric value that specifies the value to be
set for the variable on the remote node.
long BaudRate:
Baud rate to be set
short DataBits:
Number of bits per character transferred
short StopBits:
Number of stop bits at the end of each character
short Parity:
Parity mode of the port (0=>none, 1=>odd, 2=> even)
VARIANT Port:
Optional numeric value that specifies the port to set
(0..3)
VARIANT Control:
Optional numeric value that specifies whether to ena-
ble or disable handshaking on this port

Table of Contents