4-11
IM 760201-01E
Measurement Conditions
3
2
1
4
5
6
7
8
9
10
11
12
13
14
App
Index
The table below shows actual voltage and current range combinations and the power
ranges that result from them. The values are based on the table on the previous page
(when the voltage and current ranges of each element are the same). The table shows
the active power range (unit: W). The same ranges are set for apparent power (unit: VA)
and reactive power (unit: var). Just replace the unit with VA or var.
•
When the crest factor is set to 3 (see section 4.11 for details)
500.00m
1.0000
2.0000
5.0000
10.000
20.000
40.000
Active Power Range of Each Element
Current Range
Voltage Range (V)
15.000 30.000 60.000 100.00 150.00 300.00 600.00 1000.0
7.500 W
15.000 W
30.000 W
75.00 W
150.00 W
300.00 W
600.00 W
15.000 W
30.000 W
60.000 W
150.00 W
300.00 W
600.00 W
1.2000 kW
30.000 W
60.000 W
120.00 W
300.00 W
600.00 W
1.2000 kW
2.4000 kW
50.000 W
100.00 W
200.00 W
500.00 W
1.0000 kW
2.0000 kW
4.0000 kW
75.00 W
150.00 W
300.00 W
0.7500 kW
1.5000 kW
3.0000 kW
6.0000 kW
150.00 W
300.00 W
600.00 W
1.5000 kW
3.0000 kW
6.0000 kW
12.000 kW
300.00 W
600.00 W
1.2000 kW
3.0000 kW
6.0000 kW
12.000 kW
24.000 kW
500.00 W
1.0000 kW
2.0000 kW
5.0000 kW
10.000 kW
20.000 kW
40.000 kW
(A)
500.00m
1.0000
2.0000
5.0000
10.000
20.000
40.000
15.000 W
30.000 W
60.000 W
150.00 W
300.00 W
600.00 W
1200.00 W
30.000 W
60.000 W
120.000 W
300.00 W
600.00 W
1200.00 W
2.4000 kW
60.000 W
120.000 W
240.00 W
600.00 W
1200.00 W
2.4000 kW
4.8000 kW
100.000 W
200.00 W
400.00 W
1000.00 W
2.0000 kW
4.0000 kW
8.0000 kW
150.00 W
300.00 W
600.00 W
1.5000 kW
3.0000 kW
6.0000 kW
12.0000 kW
300.00 W
600.00 W
1200.00 W
3.0000 kW
6.0000 kW
12.0000 kW
24.000 kW
Active Power Range of a Wiring Unit with a 1P3W or 3P3W system, or a 3P3W system with a 3P3W (3V3A) Method
Current Range
Voltage Range (V)
600.00 W
1200.00 W
2.4000 kW
6.0000 kW
12.0000 kW
24.000 kW
48.000 kW
1000.00 W
2.0000 kW
4.0000 kW
10.0000 kW
20.000 kW
40.000 kW
80.000 kW
15.000 30.000 60.000 100.00 150.00 300.00 600.00 1000.0
(A)
500.00m
1.0000
2.0000
5.0000
10.000
20.000
40.000
22.500 W
45.000 W
90.000 W
225.00 W
450.00 W
900.00 W
1800.00 W
45.000 W
90.000 W
180.000 W
450.00 W
900.00 W
1800.00 W
3.6000 kW
90.000 W
180.000 W
360.00 W
900.00 W
1800.00 W
3.6000 kW
7.2000 kW
150.000 W
300.00 W
600.00 W
1500.00 W
3.0000 kW
6.0000 kW
12.0000 kW
225.00 W
450.00 W
900.00 W
2.2500 kW
4.5000 kW
9.0000 kW
18.0000 kW
450.00 W
900.00 W
1800.00 W
4.5000 kW
9.0000 kW
18.0000 kW
36.000 kW
Active Power Range of a Wiring Unit with a 3P4W Wiring System
Current Range
Voltage Range (V)
900.00 W
1800.00 W
3.6000 kW
9.0000 kW
18.0000 kW
36.000 kW
72.000 kW
1500.00 W
3.0000 kW
6.0000 kW
15.0000 kW
30.000 kW
60.000 kW
120.000 kW
15.000 30.000 60.000 100.00 150.00 300.00 600.00 1000.0
(A)
4.4 Setting the Measurement Range for Direct Input