Standard Default Parameters A - 11
USPS 4CB/One Code/Intelligent Mail 592 F1h 50h Disable
12-78
UPU FICS Postal 611 F1h 63h Disable
12-78
Mailmark 1337 F8h 05h 39h Disable
12-79
GS1 DataBar (formerly RSS, Reduced Space Symbology)
GS1 DataBar (GS1 DataBar
Omnidirectional, GS1 DataBar
Truncated, GS1 DataBar Stacked,
GS1
DataBar Stacked Omnidirectional)
338 F0h 52h Enable
12-80
GS1 DataBar Limited 339 F0h 53h Enable
12-81
GS1 DataBar Expanded (GS1 DataBar
Expanded, GS1 DataBar Expanded
Stacked)
340 F0h 54h Enable
12-82
Convert GS1 DataBar to UPC/EAN 397 F0h 8Dh Disable
12-82
GS1 DataBar Security Level 1706 F8h 06h AAh Level 1
12-83
GS1 DataBar Limited Margin Check 728 F1h D8h 3
12-84
Composite
Composite CC-C 341 F0h 55h Disable
12-85
Composite CC-A/B 342 F0h 56h Disable
12-85
Composite TLC-39 371 F0h 73h Disable
12-86
Composite Inverse 1113 F8h 04h 59h Regular
12-86
UPC Composite Mode 344 F0h 58h Never Linked
12-87
Composite Beep Mode 398 F0h 8Eh Beep As Each Code
Type is Decoded
12-88
GS1-128 Emulation Mode for UCC/EAN
Composite Codes
427 F0h ABh Disable
12-88
2D Symbologies
PDF417 15 0Fh Enable
12-89
MicroPDF417 227 E3h Disable
12-89
Code 128 Emulation 123 7Bh Disable
12-90
Data Matrix 292 F0h 24h Enable
12-91
Table A-1
Standard Default Parameters Table (Continued)
Parameter
Parameter
Number
SSI Number Default
Page
Number
1
User selection is required to configure this interface and this is the most common selection.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 Series and is the answer not in the manual?

Zebra DS457 Series Specifications

General IconGeneral
ConnectivityUSB, RS-232
Decode Capability1D, 2D, PDF417, Postal Codes
Scan RateUp to 60 scans per second
Supported Barcode TypesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix, PDF417, Postal Codes
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
Power Consumption2.5 W (typical)