3. Slide the grommet onto the cable and ensure that the grommet fits tightly to 
prevent water from entering the cabinet.
NOTE – If cables are entered through the cabinet floor, the grommets can be 
discarded.
4. If necessary, remove the entry plate and push the cable through the entry 
holes.
5. Prepare standard cables according to Fig. 6-20.
6. Prepare EXU cables according to Fig. 6-20.
The orientation of the EMC plates in both scenarios is the same for top and 
bottom cable entries, ie, the sealing grommets face upwards.
Figure 6-20 Preparing cables for EMC plates: (A) cables with an outer screen or 
shield, (B) cables without an outer screen or shield or (C) cables in an EXU cabinet
1) Grommet
2) EMC sleeve
3) Cable tie
4) Heat-shrinkable termination
5) Outer cable sheath
6) Entry plate
7) Conductor insulation removed to expose 
cable shield
8) Cable screen extension to connect to 
the PE busbar
9) Cable clamp
1
4
7