PREVENTIVE AND CORRECTIVE MAINTENANCE
PRODUCT
ACS6000
DOCUMENT KIND
User manual
DOCUMENT ID.
3BHS212794 E01
REV.
N
LANG.
en
PAGE
234/266
10.4.9.1. Removing the busbar connectors
Figure 10-18 Tools for removing the busbar connectors
WARNING Hazardous voltages!
Verify that the drive system is de-energized
Connect grounding sets at the locations indicated in Fig. 10-20.
Be aware of arcing between ground clamp and busbar ground studs
when connecting a grounding set to the busbars for the motor cables.
Arcing can be caused by voltages being fed into the drive when the
motor is driven by the propeller of the ship.
Follow local safety procedures
1) Orientation of lever for removing busbar
connectors
2) Orientation of lever for fitting the busbar
connectors
3) Four-way grounding set (4x)
4x
1
2
3

Table of Contents