8.10.4. Starting the drive system after an emergency-off
1. To start the drive system after an emergency-off, unlatch the 
EMERGENCY-OFF push button. 
The EMERGENCY-OFF push button returns to its initial position when turned 
into the direction indicated by the arrows on the push button.
2. Press the EMERGENCY-OFF RESET button to reset the emergency-off safety 
relay of the drive.
• The drive remains in emergency-off state until the DC-link voltage has 
dropped to < 50 V (discharged).
• After resetting, the status message of the drive changes to “ReadyOn”.
The status line of the CDP control panel shows the following:
3. The main power supply can be connected to the drive again and the drive 
system can be started up.
Alternating display message:
– EmergencyOff
– EOFF<DCVolt
1 L ->  600.0 rpm
StateINU EmergencyOff
MOTOR SP  0.00 rpm
POWER 0.0 kW