PREVENTIVE AND CORRECTIVE MAINTENANCE
PRODUCT
ACS6000
DOCUMENT KIND
User manual
DOCUMENT ID.
3BHS212794 E01
REV.
N
LANG.
en
PAGE
241/266
3. Remove the bolts (4) on each side of the phase module.
Figure 10-23 Phase module removal
4. Place the lifting table in front of the phase module.
5. Adjust the height of the table so that it is level with the rails on the underside
of the phase module.
6. Pull the phase module onto the table.
CAUTION! A phase module weighs approximately 190 kg. When pulling out the
phase module, make sure that the disconnected water hoses, optical fibers and
power supply leads are out of the way.
1) 1/2”
2) 80 mm
3) 17 mm
4) Location of bolts to remove
1
3
4444