Maintenance and Inspection of Air Filters
AdeptModules Instruction Handbook, Volume 1: Adept MV Controller Interface, Rev. A 107
5.4 Maintenance and Inspection of Air Filters
Adept MV-19 Controller Fan Filter Inspection and Cleaning
CAUTION: If the fan stops working or the filter becomes dirty, the
controller could overheat and cause a thermal failure. This applies to all
models of Adept MV controllers.
The air filter located on the front of the chassis should be inspected regularly and cleaned
at the first sign of dust or dirt buildup. The filter must be inspected and cleaned at least
once per month. Regular cleaning will prolong the life of the filter. If the filter becomes
clogged or unusable for any reason, you will need to order a new air filter; the Adept part
number is 40330-11190.
1. Turn off the controller.
2. Open the front grille by loosening two screws and swinging the grille out.
3. Pull the air filter out and inspect for dust or dirt particles. If cleaning is required,
use compressed air to clean the filter. (Follow appropriate safety procedures
regarding use of compressed air.)
4. Replace the cleaned air filter and secure the grille.
Adept MV-5/MV-10 Controller Fan Filter Inspection and Cleaning
The air filter located on the front of the chassis should be inspected regularly and cleaned
at the first sign of dust or dirt buildup. The filter must be inspected and cleaned at least
once per month. Regular cleaning will prolong the life of the filter. If the filter becomes
clogged or unusable for any reason, you will need to order a new air filter; the Adept part
number is 40340-00030.
1. Turn off the controller.
2. Loosen the two screws on the fan filter cover to gain access to the filter.
3. Pull the air filter out and inspect for dust or dirt particles. If cleaning is required,
use compressed air to clean the filter. (Follow appropriate safety procedures
regarding use of compressed air.)
4. Replace the cleaned air filter and secure the filter holder.
Adept PA-4 Amplifier Chassis Fan Filter Inspection and Cleaning
The air filter located on the front of the chassis should be inspected regularly and cleaned
at the first sign of dust or dirt buildup. The filter must be inspected and cleaned at least
once per month. Regular cleaning will prolong the life of the filter. If the filter becomes
clogged or unusable for any reason, you will need to order a new air filter. The part
number for the filter is 40330-11200.
!
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com