Diagnosing Switch Problems Monitoring Switch Health
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 34-38
Configuring Sampling Intervals
The sampling interval is the period of time between polls of the switch’s consumable resources to
monitor performance vis-a-vis previously specified thresholds. The health interval command can be used
to configure the sampling interval between health statistics checks.
To configure the sampling interval, enter the health interval command, followed by the number of
seconds.
For example, to specify a sampling interval value of 6 seconds, enter the following command:
-> health interval 6
Valid values for the seconds parameter include 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, or 30.
Viewing Sampling Intervals
The show health command can be used to display the current health sampling interval (period of time
between health statistics checks), measured in seconds.
To view the sampling interval, enter the show health configuration command. The currently configured
health sampling interval (measured in seconds) is displayed, as shown below:
-> show health configuration
Rx Threshold = 80,
TxRx Threshold = 80,
Memory Threshold = 80,
CPU Threshold = 80,
Sampling Interval (Secs) = 10
Note. If the sampling interval is decreased, switch performance be affected.