Configuring IP IP Configuration
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 15-29
The above functions and how to set their values are covered in the sections that follow.
Setting Penalty Values
You can set a penalty value for the following types of traffic:
TCP/UDP packets bound for closed ports.
TCP traffic bound for open ports.
UDP traffic bound for open ports.
Each type has its own command to assign a penalty value. Penalty values can be any non-negative integer.
Each time a packet is received that matches an assigned penalty, the total penalty value for the switch is
increased by the penalty value of the packet in question.
To assign a penalty value to TCP/UDP packets bound for a closed port, use the ip dos scan close-port-
penalty command with a penalty value. For example, to assign a penalty value of 10 to TCP/UDP packets
destined for closed ports, enter the following:
-> ip dos scan close-port-penalty 10
To assign a penalty value to TCP packets bound for an open port, use the ip dos scan tcp open-port-
penalty command with a penalty value. For example, to assign a penalty value of 10 to TCP packets
destined for opened ports, enter the following:
-> ip dos scan tcp open-port-penalty 10
To assign a penalty value to UDP packets bound for an open port, use the ip dos scan udp open-port-
penalty command with a penalty value. For example, to assign a penalty value of 10 to TCP/UDP packets
destined for closed ports, enter the following:
-> ip dos scan udp open-port-penalty 10
DoS Settings
UDP/TCP closed = 10
UDP open =20
TCP open = 5
Threshold = 2000
Decay = 2
Minute 2 Penalty Total = 2150
Generate DoS
Attack Warning
Trap
10 TCP closed port packets
10 UDP closed port packets
100 UDP open port packets

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniSwitch 6860 Series and is the answer not in the manual?

Alcatel-Lucent OmniSwitch 6860 Series Specifications

General IconGeneral
ModelOmniSwitch 6860 Series
CategorySwitch
Maximum Ports48
Switching CapacityUp to 176 Gbps
Operating SystemAOS (Alcatel-Lucent Operating System)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Relative Humidity5% to 95% non-condensing
Port Types10/100/1000BASE-T, SFP+, QSFP+
Ports24, 48
Power over Ethernet (PoE)Yes
StackingYes
Operating Temperature0°C to 50°C (32°F to 122°F)
Form Factor1U rack-mountable
MAC Address Table Size32, 000
Jumbo Frame SupportYes
Dimensions (W x D x H)440 mm x 420 mm x 44 mm (17.3 in x 16.5 in x 1.73 in)
Power SupplyAC or DC (depending on model)
Power ConsumptionVaries by model and configuration