Configuring Access Guardian Using Guest Tunneling
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 28-92
GTTS-1:
-> ip interface “Loopback0” 30.0.0.2
-> vlan 50
-> vlan 50 members port 1/1/3 tagged
-> vlan 50 members port 1/1/4 untagged
-> service l2profile Guest-l2profile stp drop 802.1x drop 802.1ab drop 802.3ad drop
gvrp drop mvrp drop amap drop
-> service access port 1/1/2 l2profile Guest-l2profile vlan-xlation enable
description “Guest Loopback Port”
-> service 100 l2gre vpnid 10 vlan-xlation enable remove-ingress-tag enable admin-
state enable description “Guest Service”
-> service 100 sap port 1/1/2:50 trusted admin-state enable description “Guest SAP
VLAN 50”
-> service sdp 20 l2gre far-end 10.0.0.1 admin-state enable description “Guest SDP
10.0.0.1”
-> service sdp 21 l2gre far-end 20.0.0.1 admin-state enable description “Guest SDP
20.0.0.1”
-> service 100 bind-sdp 20 21