3.2.1.6.2.2 Fault LED
Issue - CD-TOUCHAS is unable to connect by Ateis Studio
The situation happens when the CD-TOUCH has lost communication with audio processor.
Please follow the instruction in How to Solve chapter and check whether the solution meets your
requirements.
LED indicators:
The FAULT LED blinks when the CD-TOUCHAS has lost communication with audio processor.
First, check the information and diagnosed description displayed on [Status Bar] of CD-
TOUCHAS, then move to the following steps listed below and find out the solution that meets
your problem.
1. Check whether the CD-TOUCHAS has been connected with audio processor in the
configuration table.
2. Check whether the RS485 protocol on [Machine Setting] function has been selected to
[PSS/RWD AIO] option, and meets your installed port for PSS AS (this setting is only for
Ateis Global version software)
3. If the device still cannot work with the audio processor, it might result from the broken
device or cables. When facing this problem, please contact our Ateis Local personnel.