System Products 151
© 2020, ATEÏS. All rights reserved.
3.2.5.2.4 Reset Configuation
Sometimes if URC-200 power on with error, it needs to ignore current configuration, and reset to the
default status. Holds on both two keys on the panel, and plugs the ethernet wire to URC-200 to
power on. See the following demonstration.
After powered up, you'll see a message on the
top of LCD screen: "No Preset".
It means the URC-200 now is forbidden to run
the configuration. And then you can save
another configuration for the device to make it
working.
3.2.5.3 Maintenance
This topic contains the knowledge about the update procedure and inner settings of devices. For
example the IP settings.
3.2.5.3.1 Update Firmware
Please follow the steps below to update the firmware of URC-200:
1. Run the software and search URC-200. Click
[Network] page. Set the network interface card
that communicate with URC-200. After the network
interface card is selected, the IP address is
refreshed automatically.
2. Click [Remote Device] page. This page lists all
devices in the network. Press [Search] to
discovery URC-200s throughout the network.