Control Window
Element Description
Bypass: Disable this module's function.
Gain Reduction: Display the gain of output volume.
Pre-Processing
o Threshold: When the input volume is larger than the
Pre-Processing Threshold, it will decrease the volume to
[Threshold].
o Attack Time: The needed time for changing the volume
from the original level to the expected level.
o Release Time: The needed time for changing the volume
from the expected level to the original level.
Post-Processing
o Threshold: When the input volume is smaller than the
Post-Processing Threshold, it will suppress the echo
sound that has left.
o Attack Time: The needed time for changing the volume
from the original level to the expected level.
o Release Time: The needed time for changing the volume
from the expected level to the original level.
6.13 Logic
6.13.1 AND
Allow the logical operation "AND" that applied on a logic signal.
6.13.2 Batcher
Allow to make multiple sets of inputs and outputs simultaneously. The status of output will be
automatically clear as 0 after 1 second.
The number of input and output channels must be the same when using the Batcher component.