EasyManuals Logo

Ateis IDA8 Series User Manual

Ateis IDA8 Series
535 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #180 background imageLoading...
Page #180 background image
IDA8 Global-Net User Manual180
© 2020, ATEÏS. All rights reserved.
3.3.7.4 PDC
Full & Partial Redundancy
From IDA8 to RU-MAIN:
o IDA8: PDC1~4.
o RU-MAIN: P_PDC1, S_PDC1.
From RU-MAIN to PPM-IT5/PSS-AS etc.
o RU-MAIN: PDC1.
3.3.7.5 Normal/Backup Amplifier Input
3.3.7.5.1 Matrix Mode
Full & Partial Redundancy
Normal AMP input from IDA8C to RU-MAIN:
o IDA8C: AMP Inputs Zone1~8.
o RU-MAIN: AMP Inputs For Zone1~8 (P_ZONE, S_ZONE).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ateis IDA8 Series and is the answer not in the manual?

Ateis IDA8 Series Specifications

General IconGeneral
BrandAteis
ModelIDA8 Series
CategorySecurity System
LanguageEnglish

Related product manuals