7.1.19 File Corruption
The file CRC check code fails (if the file monitoring has been enabled in ATEIS Studio).
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o The text messages display at the touch screen of the IDA8C:
"File Corruption"
"File xxx Corruption" (where xxx = file name)
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.20 ModBus Offline
The Modbus client can't communicate.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "ModBus Offline" message displays at the touch screen of the IDA8C.
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Check the Modbus client communication. Once it's recovered, the LOG will
show: "ModBus Online."
7.1.21 AMP Rating Fault
The IDA8 gets the reference value which is too low.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o The text messages display at the touch screen of the IDA8C:
"AMP Rating Fault"