Master: Select to enable the unit as a matrix device.
5. Select the application of each amplifier.
There are three types of mode (Equal Mode, Unequal Mode, Backup Sharing Mode) which
provide users with a multi-functional combination for preference.
In case you might face any common issue of how these three types work, see Installation
Notes chapter.
6. Select as a backup Amplifier (this function shall only be displayed and adjusted under the use
of economic mode).
Normal Use: Select to enable the backup amplifier as Voice or Music sources simultaneously
when the backup amplifier is vacant currently.
5.7.3 Procedure of Monitoring Setup
The connection wiring of hardware has completed before the monitoring setup, as the IDA8C/S will
get the values from the hardware's initial state for reference. When the system is operating and
reference values are correctly achieved, the IDA8C/S continuously measures the internal status and
compares it with referenced values to determine if there are incorrect processes of zone/amplifiers.
1. Setup hardware equipment, including an IDA8C/S, a normal amplifier, a backup amplifier,
speakers and wiring between the devices,
2. Create a configuration using Ateis Studio.
3. Store the configuration, then online.