3.3.7.6 Normal/Backup Amplifier Output
3.3.7.6.1 Matrix Mode
Full & Partial Redundancy
Normal AMP Output from IDA8C to RU-MAIN:
o IDA8C: Zone1~8 AMP O.
o RU-MAIN: Zone1~8 (P_AMPO, S_AMP O).
Normal AMP Output from RU-MAIN to SPA:
o RU-MAIN: Zone1~8 (AMP O)
o SPA: Audio Output.
Backup AMP Output from IDA8C to RU-MAIN:
o IDA8C: Backup AMP1 (AMP O).
o RU-MAIN: Backup AMP1 (P_AMPO, S_AMP O).
Backup AMP Output from RU-MAIN to SPA.
o RU-MAIN: Backup AMP1 (AMP O).
o SPA: Audio Output.