Fault List & Troubleshooting 471
© 2020, ATEÏS. All rights reserved.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.24 Global AteisNet Backup Mode
One of the global ATEIS net port has broken.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "Global AteisNet Backup Mode" message displays at the touch screen of the IDA8C.
o A text message displays on the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.25 Bypass Mode
If using a redundancy unit, the IDA8 will enter in the bypass mode when a Bypass Mode fault
occurs, the following table listed the Bypass Mode faults.
Bypass Mode Fault
Flash Error
I2C Error
SSI Error
SPI Flash Error
NetCard Error
DSP Boot Failure
DSP Boot Error
Power Error
AESEBU Boot Error
TEL Boot Error
License deact
Main Board FPGA Boot Error
Ethernet Broken
DSP SDRAM Error
DSP No Response
DSP Fault
If not, the IDA8 will enter in that mode only when the "Bypass Input line" on the rear panel has
broken.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.