Fault List & Troubleshooting 473
© 2020, ATEÏS. All rights reserved.
7.1.28 Modan Offline
The Modan client can't communicate.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o The text messages display at the touch screen of the IDA8C:
"Modan Offline"
"Modan Port: n offline" (Where n = 1~65535)
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.29 NTP Server Error
All the NTP server can't communicate.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "NTP Server Error" messages display at the touch screen of the IDA8C.
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.30 Normal AMP Out of Toler
The reference value measured from the normal amplifier is out of tolerance.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o The text messages display at the touch screen of the IDA8C:
"Normal AMP Out of Toler"
"Zone n Normal AMP Gain Too High"
"Zone n Normal AMP Gain Too Low " (Where n = 1~8)