Version 7.2 1029 Mediant 1000B Gateway & E-SBC
User's Manual 65. Configuration Parameters Reference
Parameter Description
For the ini file parameter, the x denotes the port number, where 0
represents Port I. For example,
GroundKeyDetection_0 = 1
GroundKeyDetection_1 = 0
GroundKeyDetection_2 = 0
[0] Disable = (Default) Port uses loop-start signaling.
[1] Enable = Port uses ground-start signaling.
For more information, see Configuring Ground- or Loop-Start Signaling
per Analog Port on page 215.
Note:
For the parameter to take effect, a device reset is required.
To configure the same signaling method for all ports, use the ini file
parameter GroundKeyDetection.
[EnableAutoRAITransmitB
ER]
Enables the device to send a remote alarm indication (RAI) when the bit
error rate (BER) is greater than 0.001.
[0] Disable (default)
[1] Enable
Ignore BRI LOS Alarm
ignore-bri-los-alarm
[IgnoreBRILOSAlarm]
Enables the device to ignore LOS alarms received from the BRI user-
side trunk and attempts to make a call (relevant for IP-to-Tel calls).
[0] Disable
[1] Enable (default)
Note: The parameter is applicable only to BRI interfaces.
65.3.2 SIP Test Call Parameters
The SIP Signaling Test Call parameters are described in the table below.
Table 65-19: SIP Test Call Parameters
Parameter Description
Test Call DTMF String
configure troubleshoot >
test-call settings > testcall-
dtmf-string
[TestCallDtmfString]
Defines the DTMF tone that is played for answered test calls (incoming
and outgoing).
The DTMF string can be up to 15 strings. The default is "3212333". If no
string is defined (empty), DTMF is not played.
Test Call ID
configure troubleshoot >
test-call settings > testcall-
id
[TestCallID]
Defines the test call prefix number (ID) of the simulated phone on the
device. Incoming calls received with this called prefix number are
identified as test calls.
This can be any string of up to 15 characters. By default, no number is
defined.
Note:
The parameter is only for testing incoming calls destined to this prefix
number.
This feature is applicable to all applications (Gateway and SBC).
Test Call Rules Table
Test Call Rules Defines Test Call rules.