User's Manual  864  Document #: LTRT-27055 
 
  Mediant 1000B Gateway & E-SBC 
  To restore factory defaults through Web interface: 
1.  Open the Configuration File page: 
•  Toolbar: From the Actions drop-down menu, choose Configuration File. 
•  Navigation tree: Setup menu > Administration tab > Maintenance folder > 
Configuration File. 
Figure  49-1: Restoring Factory Defaults through Web 
 
2.  To keep your current IP network settings, select the Preserve Network 
Configuration check box. To overwrite all your IP network settings with the default IP 
network interface, clear the Preserve Network Configuration check box.  
3.  Click the Restore Defaults button; a message appears requesting you to confirm. 
4.  Click OK to confirm or Cancel to return to the page. 
5.  Once the device is restored to factory defaults, reset the device for the settings to take 
effect. 
 
49.3  Restoring Defaults using Hardware Reset Button 
You can restore the device to factory defaults by pressing the device's hardware reset 
pinhole button.  
  To restore default settings using the hardware reset pinhole button: 
  With a paper clip or any other similar pointed object, press and hold down the reset 
pinhole button, located on the CRMX module for at least 12 seconds (but no more 
than 25 seconds). 
 
49.4  Restoring Defaults through ini File 
You can restore the device to factory defaults, by loading an empty ini file to the device. 
This is done using the Web interface's Configuration File page (see ''Configuration File'' on 
page  827). If the ini  file includes parameter settings, ensure that they are on lines 
beginning with comment signs (i.e., semicolons ";") so that the device ignores them. 
 
 
Note:  The only settings that are not restored to default are the management (OAMP) 
LAN IP address and the Web interface's login username and password.