User's Manual 78 Document #: LTRT-27055
Mediant 1000B Gateway & E-SBC
Parameter Description
Session Timeout
session-timeout
[WebUsers_SessionTimeout]
Defines the duration (in minutes) of inactivity of a logged-in user in the
Web interface, after which the user is automatically logged off the
Web session. In other words, the session expires when the user has
not performed any operations (activities) in the Web interface for the
configured timeout duration.
The valid value is 0 to 100000. A value of 0 means no timeout. The
default value is according to the settings of the WebSessionTimeout
global parameter (see 'Configuring Web Session and Access Settings'
on page 79).
Block Duration
block-duration
[WebUsers_BlockTime]
Defines the duration (in seconds) for which the user is blocked when
the user exceeds a user-defined number of failed login attempts.
The valid value is 0 to 100000, where 0 means that the user can do as
many login failures without getting blocked. The default is according to
the settings of the 'Deny Authentication Timer' parameter (see
'Configuring Web Session and Access Settings' on page
79).
Note:
To enable this feature, see the 'Deny Access On Fail Count'
parameter in 'Configuring Web Session and Access Settings' on
page 79.
The 'Deny Authentication Timer' parameter relates to failed Web
logins from specific IP addresses.
6.5 Displaying Login Information upon Login
You can enable the device to display login information immediately upon Web login.
To enable display of user login information upon login:
1. Open the Web Settings page (Setup menu > Administration tab > Web & CLI folder
> Web Settings).
2. Under the Security group, from the 'Display Last Login Information' drop-down list,
select Enable.
3. Click Apply.
Once enabled, each time you login to the device, the Login Information window is
displayed, as shown in the example below:
Figure 6-31: Login Information Window
To close the window, click Close.