Version 7.2 999 Mediant 1000B Gateway & E-SBC
User's Manual 65. Configuration Parameters Reference
65 Configuration Parameters Reference
The device's configuration parameters, default values, and their descriptions are
documented in this section.
Note: Parameters and values enclosed in square brackets [...] represent the ini file
parameters and their enumeration values.
65.1 Management Parameters
This section describes the device's management-related parameters.
65.1.1 General Parameters
The general management parameters are described in the table below.
Table 65-1: General Management Parameters
Parameter Description
[WebLoginBlockAutoComplete]
Disables autocompletion when entering the management login
username in the 'Username' field of the device's Web interface.
Disabling autocompletion may be useful for security purposes by
hiding previously entered usernames and thereby, preventing
unauthorized access to the device's management interface.
[0] Disable = (Default) Autocompletion is enabled and the
'Username' field automatically offers previously logged in
usernames.
[1] Enable = Autocompletion is disabled.
[EnforcePasswordComplexity] Enables the enforcement of management login-password
complexity requirements to ensure strong passwords.
[0] Disable (default)
[1] Enable
For more information on password complexity requirements, see
the 'Password' parameter in Configuring Management User
Accounts on page 74.
[CustomerSN] Defines a serial number (S/N) for the device.
Note: The device's original S/N is automatically added at the end of
the configured S/N. For example, if the original S/N is 8906721 and
the configured S/N is "abc123", the resultant S/N is
"abc1238906721".
Access List Table
configure network >
access-list
[WebAccessList_x]
This table configures up to ten IP addresses that are permitted to
access the device's Web interface and Telnet interfaces. Access
from an undefined IP address is denied. When no IP addresses are
defined in this table, this security feature is inactive (i.e., the device
can be accessed from any IP address).
The default is 0.0.0.0 (i.e., the device can be accessed from any IP
address).
For example: