Version 7.2 1165 Mediant 1000B Gateway & E-SBC
User's Manual 65. Configuration Parameters Reference
Parameter Description
(Q.931 Setup).
[64] VOICE CONN RS = The device sends a Connect
(answer) message on incoming Tel calls.
[2048] CHAN ID IN FIRST RS = The device sends Channel
ID in the first response to an incoming Q.931 Call Setup
message. Otherwise, the Channel ID is sent only if the
device requires changing the proposed Channel ID.
[4096] USER SETUP ACK = (Default) The Setup Ack
message is sent by the SIP Gateway application layer and
not automatically by the PSTN stack.
[8192] CHAN ID IN CALL PROC = The device sends
Channel ID in a Q.931 Call Proceeding message.
[65536] PROGR IND IN SETUP ACK = (Default) The
device includes Progress Indicator (PI=8) in Setup Ack
message if an empty called number is received in an
incoming Setup message. This option is applicable to the
overlap dialing mode. The device also plays a dial tone (for
TimeForDialTone) until the next called number digits are
received.
[2147483648] USER SCREEN INDICATOR = When the
device receives two Calling Number IE's in the Setup
message, the device, by default, uses only one of the
numbers according to the following:
Network provided, Network provided - the first calling
number is used
Network provided, User provided: the first one is used
User provided, Network provided: the second one is
used
User provided, user provided: the first one is used
When this bit is configured, the device behaves as follows:
Network provided, Network provided: the first calling
number is used
Network provided, User provided: the second one is
used
User provided, Network provided: the first one is used
User provided, user provided: the first one is used
Note:
In the Web interface, the parameter displays the summation
of the enabled optional bit values, in hex format. For
example, the default value is 0x11000 (69632 in decimal),
which is the summation of the two bit options, USER
SETUP ACK (0x01000 or 4096 in decimal) and PROGR
IND IN SETUP ACK (0x10000 or 65536 in decimal) that are
enabled by default (i.e., 4096 + 65536 = 69632).
When using the ini file to configure the device to support
several ISDNInCallsBehavior features, enter a summation
of the individual feature values. For example, to support
both [2048] and [65536] features, set ISDNInCallsBehavior
= 67584 (i.e., 2048 + 65536).
[ISDNInCallsBehavior_x] Same as the description for the parameter
ISDNInCallsBehavior, but per trunk (i.e., where x denotes the
Trunk ID).