EasyManua.ls Logo

AudioCodes Mediant 1000B - Page 1256

AudioCodes Mediant 1000B
1281 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User's Manual 1256 Document #: LTRT-27055
Mediant 1000B Gateway & E-SBC
Parameter Description
Profiles'' on page 423.
Note: If this functionality is configured for a specific IP Profile,
the settings of this global parameter is ignored for calls
associated with the IP Profile.
[AMDTimeout] Defines the timeout (in msec) between receiving Connect
messages from the Tel side and sending AMD results.
The valid range is 1 to 30,000. The default is 2,000 (i.e., 2
seconds).
AMD Beep Detection Mode
configure voip > sip-definition
settings > amd-beep-detection
[AMDBeepDetectionMode]
Determines the AMD beep detection mode. This mode detects
the beeps played at the end of an answering machine
message, by using the X-Detect header extension. The device
sends a SIP INFO message containing the field values
Type=AMD and SubType=Beep. This feature allows users of
certain third-party, Application server to leave a voice message
after an answering machine plays the “beep”.
[0] Disabled (default)
[1] Start After AMD
[2] Start Immediately
Answer Machine Detector Beep
Detection Timeout
configure voip > media ipmedia >
amd-beep-detection-timeout
[AMDBeepDetectionTimeout]
Defines the AMD beep detection timeout (i.e., the duration that
the beep detector functions from when detection is initiated).
This is used for detecting beeps at the end of an answering
machine message.
The valid value is in units of 100 milliseconds, from 0 to 1638.
The default is 200 (i.e., 20 seconds).
Answer Machine Detector Beep
Detection Sensitivity
configure voip > media ipmedia >
amd-beep-detection-sensitivity
[AMDBeepDetectionSensitivity]
Defines the AMD beep detection sensitivity for detecting beeps
at the end of an answering machine message.
The valid value is 0 to 3, where 0 (default) is the least sensitive.
early-amd
[EnableEarlyAMD]
Enables AMD detection to be activated upon receipt of an
ISDN Alerting or Connect message.
[0] = (Default) Disable - AMD is activated upon receipt of
ISDN Connect message.
[1] = Enable - AMD is activated upon receipt of ISDN
Alerting message.
Note: The parameter is applicable only to digital interfaces.
AMD mode
configure voip > sip-definition
settings > amd-mode
[AMDmode]
Global parameter that enables the device to disconnect the IP-
to-Tel call upon detection of an answering machine on the Tel
side. You can also configure this functionality per specific calls,
using IP Profiles (IpProfile_AmdMode). For a detailed
description of the parameter and for configuring this
functionality in the IP Profiles table, see ''Configuring IP
Profiles'' on page 423.
Note: If this functionality is configured for a specific IP Profile,
the settings of this global parameter is ignored for calls
associated with the IP Profile.
Energy Detector Parameters
Enable Energy Detector
Enables the Energy Detector feature. This feature generates

Table of Contents