Version 7.2 291 Mediant 1000B Gateway & E-SBC
User's Manual 15. Services
2. Click New; the following dialog box appears:
Figure 15-52: EMS Services Table - Add Dialog Box
3. Configure an EMS Service according to the parameters described in the table below.
4. Click Apply, and then save your settings to flash memory.
Table 15-23: EMS Services Table Parameter Descriptions
Parameter Description
Index
[EMSService_Index]
Defines an index number for the new table row.
Note:
Each row must be configured with a unique index.
The parameter is mandatory.
Name
service-name
[EMSService_ServiceName]
Defines a descriptive name, which is used when associating
the row in other tables.
The valid value is a string of up to 40 characters. By default, no
value is defined.
Note:
Each row must be configured with a unique name.
The parameter is mandatory.
EMS Primary Server
primary-server
[EMSService_PrimaryServer]
Defines the address of the primary EMS server.
Note: The parameter is mandatory.
EMS Secondary Server
secondary-server
[EMSService_SecondaryServer]
Defines the address of the secondary EMS server.
Listening Interface to devices
dev-login-int
[EMSService_DeviceLoginInterface]
Assigns an HTTP Interface (local, listening HTTP
interface:port) for communication with the client. To configure
HTTP Interfaces, see ''Configuring HTTP Interfaces'' on page
285.
By default, no value is defined.
Note: The parameter is mandatory.