Chapter 4: AC Drive Parameters
Page 4–23
DURApulse GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
GS4 Parameters Summary – Display Parameters (P8.xx) – (continued)
Parameter Range
Run
Read/
Write
Modbus
Address
Settings
Hex Dec Default User
P8.11
Accumulative Motor
Operation Time (minute)
0~1439 Read 080B 42060 ~ ~
P8.12
Accumulative Motor
Operation Time (day)
0~65535 Read 080C 42061 ~ ~
P8.13
Keypad Communication
Fault Treatment
0: Warn & Continue Operation
1: Warn & Ramp to Stop
2: Warn & Coast to Stop
3: No Warning & Continue Operation
R/W 080D 42062 2
P8.14
Keypad Time Out 0�0~100�0 sec R/W 080E 42063 1�0 ~
P8.15
reserved ~ ~ 080F 42064 0 ~
P8.16
reserved ~ ~ 0810 42065 0 ~
P8.17
reserved ~ ~ 0811 42066 0 ~
P8.18
reserved ~ ~ 0812 42067 0 ~
P8.19
reserved ~ ~ 0813 42068 0 ~
P8.20
PLC Buffer 1 0~65535 R/W 0814 42069 0
P8.21
PLC Buffer 2 0~65535 R/W 0815 42070 0
P8.22
PLC Buffer 3 0~65535 R/W 0816 42071 0
P8.23
PLC Buffer 4 0~65535 R/W 0817 42072 0
P8.24
PLC Buffer 5 0~65535 R/W 0818 42073 0
P8.25
PLC Buffer 6 0~65535 R/W 0819 42074 0
P8.26
PLC Buffer 7 0~65535 R/W 081A 42075 0
P8.27
PLC Buffer 8 0~65535 R/W 081B 42076 0
P8.28
PLC Buffer 9 0~65535 R/W 081C 42077 0
P8.29
PLC Buffer 10 0~65535 R/W 081D 42078 0
P8.30
PLC Buffer 11 0~65535 R/W 081E 42079 0
P8.31
PLC Buffer 12 0~65535 R/W 081F 42080 0
P8.32
PLC Buffer 13 0~65535 R/W 0820 42081 0
P8.33
PLC Buffer 14 0~65535 R/W 0821 42082 0
P8.34
PLC Buffer 15 0~65535 R/W 0822 42083 0
P8.35
PLC Buffer 16 0~65535 R/W 0823 42084 0
P8.36
PLC Buffer 17 0~65535 R/W 0824 42085 0
P8.37
PLC Buffer 18 0~65535 R/W 0825 42086 0
P8.38
PLC Buffer 19 0~65535 R/W 0826 42087 0
P8.39
PLC Buffer 20 0~65535 R/W 0827 42088 0