Motor ParaMeters suMMary (P0.xx)
For detailed information about the P0.xx parameter group, please refer to page 4–33.
GS4 Parameters Summary – Motor Parameters (P0.xx)
Parameter Range
Run
1)
Read/
Write
Modbus
Address
Settings
Hex Dec Default
2)
User
1) in the Run-Read/Write column indicates that the parameter can be set during RUN mode.
R/W indicates “read/write.
Read indicates “read-only.
2) Parameters can be restored to their default values using P9.08.
P0.00
Motor 1 Maximum Output
Voltage
230V: 0�0~255�0V
460V: 0�0~510�0V
R/W 0000 40001
GS4 -2xxx:
230�00
GS4 -4xxx:
460�00
P0.01
Motor 1 Rated Current 10~120% drive rated Amps R/W 0001 40002
90% rated I
of GS4
P0.02
Motor 1 Base Frequency 0�00~600�00 Hz R/W 0002 40003 60�00
P0.03
Motor 1 Rated RPM 0 to (120 x P0�02/P0�09)-1 ♦R/W 0003 40004
17 10 (60Hz
4-pole)
14 10 (50Hz
4-pole)
P0.04
Drive Maximum Output
Frequency
0~600�00 Hz R/W 0004 40005 50�00/60�00
P0.05
Motor Auto Tune
0: Disable
1: Measure motor in dynamic status
(motor spinning)
2: Measure motor in static status
(motor not spinning)
R/W 0005 40006 0
P0.06
Motor 1 Resistance 0~65.535Ω R/W 0006 40007 0
P0.07
Motor 1 No-Load Current 0~100% motor rated Amps R/W 0007 40008
40% of
Motor1
Rated I
P0.08
Motor 1 Rated Horsepower (HP) 0�00~655�35hp ♦R/W 0008 40009
Rated hp of
GS4
P0.09
Motor 1 Number of Poles 2 to (120 x P0�02/P0�03) R/W 0009 40010 4
P0.10
Motor 1 or 2 Selection
1: Motor 1
2: Motor 2
R/W 000A 40011 1
P0.11
Motor 2 Maximum Output
Voltage
230V: 0�0~255�0V
460V: 0�0~510�0V
R/W 000B 40012
GS4 -2xxx:
230�00
GS4 -4xxx:
460�00
P0.12
Motor 2 Rated Current 10~120% drive rated Amps R/W 000C 40013
90% rated I
of GS4
P0.13
Motor 2 Base Frequency 0�00~600�00 Hz R/W 000D 40014 60�00
P0.14
Motor 2 Rated RPM 0 to [(120 x P0�13/P0�18)-1] rpm ♦R/W 000E 40015
17 10 (60Hz
4-pole)
14 10 (50Hz
4-pole)
P0.15
Motor 2 Resistance 0~65.535Ω R/W 000F 40016 0
P0.16
Motor 2 No-Load Current 0~100% motor rated Amps R/W 0010 40017
40% of
Motor2
Rated I
P0.17
Motor 2 Rated Horsepower (HP) 0�00~655�35 hp ♦R/W 0011 40018
Rated hp of
GS4
P0.18
Motor 2 Number of Poles 2 to (120 x P0�13/P0�14) R/W 0012 40019 4

Table of Contents

Other manuals for Automation Direct DURApulse GS4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automation Direct DURApulse GS4 and is the answer not in the manual?

Automation Direct DURApulse GS4 Specifications

General IconGeneral
BrandAutomation Direct
ModelDURApulse GS4
CategoryController
LanguageEnglish

Related product manuals