7.9.36 DeviceTemperatureStatusTransitionSelector
Selects which temperature transition is controlled by the DeviceTemperatureStatusTran-
sition feature.
Name DeviceTemperatureStatusTransitionSelector
Category DeviceControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Exceeded-
ToNormal
Temperature threshold for transition from status Exceed-
ed back to status Normal.
HighToEx-
ceeded
Temperature threshold for transition from status High to
status Exceeded.
NormalTo-
High
Temperature threshold for transition from status Normal
to status High.
NormalToHigh
freely programmable value
HighToExceed
fixed value (camera shutdown if exceeded)
ExceedToNormal
(Device Temperature < ExceededToNormal)
freely programmable value
temperature curve
Time
Temperature
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Cooling measures
recommended
7.9.37 DeviceType
Returns the device type.
Name DeviceType
Category DeviceControl
Interface IEnumeration
Access Read only
Unit -
Values Transmitter Data stream transmitter device.
7.9.38 DeviceUserID
User-programmable device identier.
Name DeviceUserID
Category DeviceControl
Interface IString
Access Read / Write
Unit -
Values e.g. "camera 1" (max. length 64)