7.18.13 SequencerTriggerSource
Species the internal signal or physical input line to use as the sequencer trigger source.
Name SequencerTriggerSource
Category SequencerControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Counter1End Starts with the reception of the Counter End.
Counter2End Starts with the reception of the Counter End.
ExposureActive Starts with the reception of the Exposure Active.
Line0 Species Line 0 as external trigger source.
Line1 (≥ Rel. 2) Species Line 1 as external trigger source.
Off Disables the sequencer trigger.
ReadOutActive Starts with the reception of the Read Out Active.
Timer1End Starts with the reception of the Timer End.