183
V2.6 | 8/30/2022 | 1120758
7.18.13 SequencerTriggerSource
Species the internal signal or physical input line to use as the sequencer trigger source.
Name SequencerTriggerSource
Category SequencerControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Counter1End Starts with the reception of the Counter End.
Counter2End Starts with the reception of the Counter End.
ExposureActive Starts with the reception of the Exposure Active.
Line0 Species Line 0 as external trigger source.
Line1 (≥ Rel. 2) Species Line 1 as external trigger source.
Off Disables the sequencer trigger.
ReadOutActive Starts with the reception of the Read Out Active.
Timer1End Starts with the reception of the Timer End.