92
V2.6 | 8/30/2022 | 1120758
7.9.4 DeviceFirmwareVersion
Version of the rmware in the device.
Name DeviceFirmwareVersion
Category DeviceControl
Interface IString
Access Read only
Unit -
Values e.g. CID:012004/PID:11208326
7.9.5 DeviceLinkCommandTimeout
Indicates the current command timeout of the specic Link.
Name DeviceLinkCommandTimeout
Category DeviceControl
Interface IFloat
Access Read only
Unit µs
Values 200,000.000000 (Increment: 1)
7.9.6 DeviceLinkHeartbeatMode
Activate or deactivate the Link`s heartbeat.
Name DeviceLinkHeartbeatMode
Category DeviceControl
Interface IEnumeration
Access Read / Write
Unit -
Values
On Enables the Link heartbeat.
Off Disables the Link heartbeat.
7.9.7 DeviceLinkHeartbeatTimeout
Controls the current heartbeat timeout of the specic Link.
Name DeviceLinkHeartbeatTimeout
Category DeviceControl
Interface IFloat
Access Read / Write
Unit µs
Values 500,000.000000 ... 4,294,967,295,000.000000 (Increment: 1)