203
V2.6 | 8/30/2022 | 1120758
7.20.4.10 PtpServoStatusThreshold
Threshold of time difference to Ptp Master Clock for transition PtpServoStatus Unknown
to Locked.
Name PtpServoStatusThreshold
Category
TansportLayerControl → PtpControl
Interface IInteger
Access Read only
Unit µs
Values 1 ... 10000 (Increment: 1)
7.20.4.11 PtpStatus
Returns the latched state of the PTP clock.
Name PtpStatus
Category
TansportLayerControl → PtpControl
Interface IEnumeration
Access Read only
Unit -
Values
Disabled PTP is disabled.
Faulty The fault state of the protocol.
Initializing PTP is being initialized.
Listening Device is listening for other PTP enabled devices.
Master Device acting as master clock.
Passive
If there are 2 or more devices with PtpMode = Master,
this device has an inferior clock and is not synchronized
to the master.
Pre_Master
The port shall behave in all respects as though it were
in the MASTER state except that it shall not place any
messages on its communication path except for Pde-
lay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, sig-
naling, or management messages.
Slave
PTP synchronization between this device and master is
achieved.
Uncalibrated PTP synchronization not yet achieved.
7.20.4.12 PtpSyncMessageInterval(≥Release3only)
Returns the latched sync message interval from the PTP master clock in milliseconds.
Name PtpSyncMessageInterval
Category
TansportLayerControl → PtpControl
Interface IFloat
Access Read only
Unit ms
Values ≥ 0