116
V2.6 | 8/30/2022 | 1120758
Signals
ExposureActive Device is doing the exposure of a Frame (or Line).
Line 0 Device is currently waiting for signal of input line 0.
Line 1 Device is currently waiting for signal of input line 1.
Off Line output is disabled (Tri-State).
ReadoutActive Device is doing the readout of a Frame.
Timer1Active The chosen Timer is in active state.
TriggerReady Device is ready for trigger.
UserOutput1
The chosen User Output Bit state as dened by its current UserOut-
putValue.
UserOutput2
The chosen User Output Bit state as dened by its current UserOut-
putValue.
UserOutput3
The chosen User Output Bit state as dened by its current UserOut-
putValue.
UserOutput4
The chosen User Output Bit state as dened by its current UserOut-
putValue.
7.10.16 LineStatus
Returns the current status of the selected input or output Line.
Name LineStatus
Category DigitalIOControl
Interface IBoolean
Access Read only
Unit -
Values
true = 1 (On)
false = 0 (Off)
7.10.17 LineStatusAll
Returns the current status of all available Line signals at time of polling in a single biteld.
Name LineStatusAll
Category DigitalIOControl
Interface IInteger
Access Read only
Unit -