EasyManua.ls Logo

Baumer VLXT - Ptpclockaccuracy; Ptpclockid; Ptpdatasetlatch

Baumer VLXT
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
200
V2.6 | 8/30/2022 | 1120758
7.20.4.1 PtpClockAccuracy
Indicates the expected accuracy of the device PTP clock when it is the grandmaster, or in
the event it becomes the grandmaster.
Name PtpClockAccuracy
Category
TansportLayerControl PtpControl
Interface IEnumeration
Access Read only
Unit -
Values see table below
Notice
The camera supports an accuracy of Within 100µs.
GreaterThan10s Within1us
Unknown Within250ms.
Within100ms Within250ns
Within100ns Within250us
Within100us Within25ms
Within10ms Within25ns
Within10s Within25us
Within10us Within2p5ms
Within1ms Within2p5us
Within1s
7.20.4.2 PtpClockID
Returns the latched clock ID of the PTP device.
Notice
Byte 0 of the IEEE ClockIdentity eld is mapped to the MSB.
Name PtpClockID
Category
TansportLayerControl PtpControl
Interface IInteger
Access Read only
Unit -
Values 80-00-00-00-00-00 ... 7F-FF-FF-FF-FF-FF-FF-FF (Increment: 1)
7.20.4.3 PtpDataSetLatch
Latches the current values from the device’s PTP clock data set.
Name PtpDataSetLatch
Category
TansportLayerControl PtpControl
Interface ICommand
Access Write only
Unit -
Values -

Table of Contents