107
V2.6 | 8/30/2022 | 1120758
7.10.1 LineDebouncerHighTimeAbs
Sets the absolute value of the selected line debouncer time in microseconds for switch
from low to high.
Name LineDebouncerHighTimeAbs
Category DigitalIOControl
Interface IFloat
Access Read / Write
Unit µs
Values 0.000000 - 5,000.000000 (Increment: 1.00)
7.10.2 LineDebouncerLowTimeAbs
Sets the absolute value of the selected line debouncer time in microseconds for switch
from high to low.
Name LineDebouncerLowTimeAbs
Category DigitalIOControl
Interface IFloat
Access Read / Write
Unit µs
Values 0.000000 - 5,000.000000 (Increment: 1.00)