7.10.9 LinePWMMaxDuration
Sets the maximum possible LinePWMDurationtime in μs. This value is specied by the 
connected lighting. [Read/Write] (max = 50000 μs)
Name LinePWMMaxDuration
Category DigitalIOControl
Interface IInteger
Access Read / Write
Unit µs
Values 1 - 50000 (Increment: 1)
7.10.10 LinePWMMaxDutyCycle
Sets the maximum possible LinePWMDutyCycle in %. This value is specied by the con-
nected illumination.
Name LinePWMMaxDutyCycle
Category DigitalIOControl
Interface IInteger
Access Read / Write
Unit %
Values 1 - 100 (Increment: 1)
7.10.11 LinePWMMode
Selects the PWM mode of the selected output line.
Name LinePWMMode
Category DigitalIOControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Fixed
Frequency
The selected output line generate a xed frequency of puls-
es starting with every transition from 0 to 1 and stopping
with every transition from 1 to 0.
Off
The PWM Mode is off. The output line acts as a normal
output.
OnePulse
The selected output line generate one pulse with every
transition from 0 to 1.