7.17.6 FocalLengthInitialize (.EF only)
Initializes the focal length and makes it ready for use. The focal length position after ini-
tialization is implementation dependent. This feature is only implemented if an additional
initialization is required after OpticControllerInitialize.
Name FocalLengthInitialize
Category OpticControl
Interface ICommand
Access Write only
Unit -
Values -
7.17.7 FocalLengthStatus (.EF only)
Reads the status of the FocalLength feature.
Name FocalLengthStatus
Category OpticControl
Interface IEnumeration
Access Read only
Unit -
Values
Busy The focal length executes a feature access/command.
Error The focal length encountered an error.
Not Connected The focal length is physically not connected.
Not Initialized The focal length is not initialized.
Not Supported
The focal length is physically connected but not sup-
ported.
Ready The focal length is ready to use.
7.17.8 FocusInitialize (.EF only)
Initializes the focus and makes it ready for use. The focus position after initialization is
implementation dependent. This feature is only implemented if an additional initialization
is required after OpticControllerInitialize.
Name FocusInitialize
Category OpticControl
Interface ICommand
Access Write only
Unit -
Values -