182
V2.6 | 8/30/2022 | 1120758
7.18.11 SequencerSetStart
Sets the initial/start sequencer set, which is the rst set used within a sequencer.
Name SequencerSetStart
Category SequencerControl
Interface IInteger
Access Read / Write
Unit -
Values 0 ... 127 (Increment: 1)
7.18.12 SequencerTriggerActivation
Denes the signals edge that triggers the sequencer.
Name SequencerTriggerActivation
Category SequencerControl
Interface IEnumeration
Access Read / Write
Unit -
Values
AnyEdge
Species that the trigger is considered valid on the falling
or rising edge of the source signal.
FallingEdge
Species that the trigger is considered valid on the falling
edge of the source signal.
LevelHigh
(≥ Rel. 2)
Species that the trigger is considered valid as long as
the level of the source signal is high.
LevelLow
(≥ Rel. 2)
Species that the trigger is considered valid as long as
the level of the source signal is low.
RisingEdge
Species that the trigger is considered valid on the rising
edge of the source signal.