7.18.11 SequencerSetStart
Sets the initial/start sequencer set, which is the rst set used within a sequencer.
Name SequencerSetStart
Category SequencerControl
Interface IInteger
Access Read / Write
Unit -
Values 0 ... 127 (Increment: 1)
7.18.12 SequencerTriggerActivation
Denes the signals edge that triggers the sequencer.
Name SequencerTriggerActivation
Category SequencerControl
Interface IEnumeration
Access Read / Write
Unit -
Values
AnyEdge
Species that the trigger is considered valid on the falling 
or rising edge of the source signal.
FallingEdge
Species that the trigger is considered valid on the falling 
edge of the source signal.
LevelHigh
(≥ Rel. 2)
Species that  the  trigger  is considered valid  as  long  as 
the level of the source signal is high.
LevelLow
(≥ Rel. 2)
Species that  the  trigger  is considered valid  as  long  as 
the level of the source signal is low.
RisingEdge
Species that the trigger is considered valid on the rising 
edge of the source signal.

Table of Contents