EasyManua.ls Logo

Baumer VLXT - Exposuretimegapmax (≥ Release 3 Only)

Baumer VLXT
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
V2.6 | 8/30/2022 | 1120758
Camera Type t
exposure
min
ExposureTimeDefault׀ShortExposureTimeEnable
t
non-selectable range
*
ExposureTimeGapMin - ExposureTimeGapMax
t
exposure
max
Monochrome
VLXT-06M.I (.JP) 7 ׀ 1 μs 6 μs 60 s
VLXT-17M.I 7 ׀ 1 μs 6 μs 60 s
VLXT-31M(.I) (.FO) 15 ׀ 1 μs 60 s
VLXT-28M.I (.JP) 8 ׀ 1 μs 6 - 7 μs 60 s
VLXT-50M(.I) (.FO) 15 ׀ 1 μs 60 s
VLXT-55M.I 5 ׀ 1 μs 4 μs 60 s
VLXT-71M.I 9 ׀ 1 μs 6 - 8 μs 60 s
VLXT-81M.I 6 ׀ 1 μs 60 s
VLXT-90M (.I) (.JP) (.FO) 15 ׀ 1 μs 60 s
VLXT-123M(.I) (.FO) 15 ׀ 1 μs 60 s
VLXT-126M.I 7 ׀ 1 μs 4 - 6 μs 60 s
VLXT-240M.I
8 ׀ 1 μs 60 s
VLXT-490M.I (.EF)
20 μs 60 s
VLXT-650M.I (.EF)
VLXN-650M.I.JP
20 μs 60 s
Color
VLXT-06C.I.JP 7 ׀ 1 μs 6 μs 60 s
VLXT-31C.I (.JP) 15 ׀ 1 μs 60 s
VLXT-50C(.I) (.FO) 15 ׀ 1 μs 60 s
VLXT-55C.I 5 ׀ 1 μs 4 μs 60 s
VLXT-71C.I 9 ׀ 1 μs 6 - 8 μs 60 s
VLXT-81C.I 6 ׀ 1 μs 6 - 8 μs 60 s
VLXT-90C.I 15 ׀ 1 μs 60 s
VLXT-123C.I 15 ׀ 1 μs 60 s
VLXT-126C.I 7 ׀ 1 μs 4 - 6 μs 60 s
VLXT-240C.I
8 ׀ 1 μs 60 s
VLXT-490C.I (.EF)
20 μs 60 s
VLXT-650C.I (.EF) 20 μs 60 s
*)
range only relevant with activated ShortExposureTimeEnable
Notice
If the ExposureTime is within the gap range (t
non-selectable range
), a value of ExposureTi-
meGapMax + 1 is automatically set.
7.1.13 ExposureTimeGapMax(≥Release3only)
Returns the maximum value of the exposure time gap.
Name ExposureTimeGapMax
Category AcqusitionControl
Interface IFloat
Access Read only
Unit μs
Values 0 - 2,000,000.000000 (Increment: 1.00)

Table of Contents