7.17.3 ApertureStatus (.EF only)
Reads the status of the Aperture feature.
Name ApertureStatus
Category OpticControl
Interface IEnumeration
Access Read only
Unit -
Values
Busy The aperture executes a feature access/command.
Error The aperture encountered an error.
Not Connected The aperture is physically not connected.
Not Initialized The aperture is not initialized.
Not Supported
The aperture is physically connected but not support-
ed.
Ready The aperture is ready to use.
7.17.4 ApertureStepper (.EF only)
ApertureStepper controls the stepper value of the Aperture. The minimum value is the
maximum aperture.
Name ApertureStepper
Category OpticControl
Interface IInteger
Access Read / Write
Unit -
Values
e.g. 42 ... 85 (Increment: 1)
value range depending on lens
7.17.5 FocalLength
Focal length in millimeters.
Name FocalLength
Category OpticControl
Interface IFloat
Access Read only
Unit mm
Values
e.g. 0 ... 4,294,967,295,000000 (Increment:1.00)
value range depending on lens