212
V2.6 | 8/30/2022 | 1120758
7.22.14 boSerialMode
States the interface mode of the serial interface.
Name boSerialMode
Category boSerialControl
Interface IEnumeration
Access Read only
Unit -
Values
Bypass
(except .EF)
UART1 of Power and Process Interface and UART0
Interface are connected.
Off The serial interface is off and shall not be used
Optic Control The serial interface shall be used for optic control.
bo Serial Con-
trol
The serial interface shall be used for bo serial control.
7.22.15 boSerialRead
Command to read data from serial interface.
Name boSerialRead
Category boSerialControl
Interface ICommand
Access Write only
Unit -
Values -
7.22.16 boSerialSelector
Selects which serial interface to congure.
UART1UART0
Name boSerialSelector
Category boSerialControl
Interface IEnumeration
Access Read / Write
Unit -
Values
UART0
Selects the UART0 Interface which can be used, for ex-
ample, to control optical components.
UART1
Selects the UART1 Interface which is part of the Power
and Process Interface and can be used for RS232 com-
munication.