7.19.4 TransferStop
Stops the streaming of data Block(s). The current block transmission will be completed.
Name TransferStop
Category TansferControl
Interface ICommand
Access Write only
Unit -
Values -
7.20 Category: TransportLayerControl
This chapter provides the Transport Layer control features.
7.20.1 EnergyEfcientEthernetEnable(≥Release2only)
Controls  whether  the  Energy  Efcient  /  Green  Ethernet  mode  (802.3az)  in  the  PHY is 
activated or not.
Notice
A device reboot is needed for changes to take effect.
Notice
By deactivating EnergyEfcientEthernetEnable (EnergyEcientEthernetEnable
= false), higher accuracy may be achieved when using PTP (PtpEnable = true).
Furthermore a reduction of the time until the system settles down (PtpServoStatus
= Locked) can be achieved.
Name EnergyEfcientEthernetEnable
Category TansportLayerControl
Interface IBoolean
Access Read / Write
Unit -
Values
true = 1 (On)
false = 0 (Off)