6.2 Sensor position accuracy
The typical accuracy by assumption of the root mean square value is displayed in the
gures and the table below:
C- / TFL-Mount
14,2
A
Z
±YR
±XR
±XM
±YM
± α
2
2
M58-Mount
±YR
±XR
±XM
±YM
Z
7,2
A
± α
EF-Mount
±YR
±XM
±YM
±XR
A
Z
40
± α