167
V2.6 | 8/30/2022 | 1120758
7.15.7 LUTContent
Describes the content of the selected LUT.
Name LUTContent
Category LUTControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Gamma
The  content  of  the  selected  LUT  is  dened  by  the 
value of the feature Gamma.
UserdenedLUT The content of the selected LUT is user dened.
7.15.8 LUTEnable
Activates the selected LUT.
Name LUTEnable
Category LUTControl
Interface IBoolean
Access Read / Write
Unit -
Values
true = 1 (On)
false = 0 (Off)
7.15.9 LUTIndex
Control the index (offset) of the coefcient to access in the selected LUT.
Name LUTIndex
Category LUTControl
Interface IInteger
Access Read / Write
Unit -
Values 0 ... 4095 (Increment: 1)
7.15.10 LUTSelector
Selects which LUT to control.
Name LUTContent
Category LUTControl
Interface IEnumeration
Access Read / Write
Unit -
Values Luminance Selects the Luminance LUT.