7.17.18 OpticControllerStatus
Reads the state of the optic controller.
Name OpticControllerStatus
Category OpticControl
Interface IEnumeration
Access Read only
Unit -
Values
Busy
The optic controller executes a feature access/com-
mand.
Error The optic controller encountered an error.
Not Connected The optic controller is physically not connected.
Not Initialized The optic controller is not initialized.
Not Supported:
The optic controller is physically connected but not
supported.
Ready The optic controller is ready to use.
7.17.19 OpticControllerTemperature (except .EF)
Optical controller temperature in degrees Celsius (C).
Name OpticControllerTemperature
Category OpticControl
Interface IFloat
Access Read only
Unit °C
Values -127.0 ... 127.0
7.17.20 OpticControllerThermalCompensation (except .EF)
The focus of the lens may change as the operating temperature increases. With this fea-
ture you enable or disable the thermal compensation of the optic controller.
Notice
Function available for Varioptic with rmware ≥ v38.
Name OpticControllerThermalCompensation
Category OpticControl
Interface IBoolean
Access Read / Write
Unit -
Values
true = 1 (On)
false = 0 (Off)