38
V2.6 | 8/30/2022 | 1120758
Gap-free assembly
Sealing rings and Harting Adapter (.FO only)
Do not forget the seals!
Recommended grease
for easier installation:
ELKALUB GLS 867
Tube
Tube Adapter
Camera
Distance Ring
The peak torque while
tightening the
screws is 0.9 Nm.
Use a torque wrench!
Harting Adapter
The peak torque while
tightening the
screws is 0.9 Nm.
Use a torque wrench!
4.7 Cables
For UL conform installations the cables used must meet the following requirements:
▪ shielding for optimum electrical noise immunity
▪ IP67 protection
▪ UL approval
▪ dielectric strength according to the operating voltages used
▪ temperature stability in the specied device temperature range
▪ minimum cross section of cable suitable for max. output current