EasyManua.ls Logo

Baumer VLXT - Cables

Baumer VLXT
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
V2.6 | 8/30/2022 | 1120758
Gap-free assembly
Sealing rings and Harting Adapter (.FO only)
Do not forget the seals!
Recommended grease
for easier installation:
ELKALUB GLS 867
Tube
Tube Adapter
Camera
Distance Ring
The peak torque while
tightening the
screws is 0.9 Nm.
Use a torque wrench!
Harting Adapter
The peak torque while
tightening the
screws is 0.9 Nm.
Use a torque wrench!
4.7 Cables
For UL conform installations the cables used must meet the following requirements:
shielding for optimum electrical noise immunity
IP67 protection
UL approval
dielectric strength according to the operating voltages used
temperature stability in the specied device temperature range
minimum cross section of cable suitable for max. output current

Table of Contents

Related product manuals